2 - 200 Horsepower Variable Torque

This P5 Drive is rated for 600 volt. The drive rated for variable torque applications with current overload rating of 120% for 60 seconds. Standard features include setpoint (PID) control, energy-savings mode, power-consumption monitoring, and harmonic distortion reduction. Ideal applications include fans, pumps, grinders, buffers, centrifuges, and saws.

This product may also be labeled GPD506/P5

Specifications and Features for P5 Drive 600 Volt


The GPD 506/P5 is designed specifically for applications where overload and starting torque requirements are well known. Common applications of this type include fans, centrifugal pumps, commercial laundry machines, grinders, buffers, low-viscosity mixers, centrifuges and saws.

  • Constant torque and variable torque ratings.
  • V/Hz Control Mode.
  • Alpha/numeric operator...Full function LCD english language operator and keypad with easy-to-read 16 character two-line format display. Easy input and monitoring of operating parameters.
  • Built-in PID control...Eliminates cost of external device. Full featured scalable PID feedback with display and an inverse signal function.
  • Energy savings control...Automatic output voltage adjustment in response to actual motor loading. Real-time energy savings based on motor algorithms. Increases motor efficiency by several percent.
  • Network Communications links to DeviceNet or ModBus RTU.
  • Under torque detection...Alerts the operator to conditions such as loss of load or broken fan belts.
  • Dual-bridge, 12-pulse rectification...By using a zig-zag input transformer with dual secondary, input current harmonic distortion factor can be reduced over 90%.
Performance Features
  • Ratings:  
    2 to 200 HP (VT) at 600 VAC
  • Overload capacity: 
    VT 120% for 60 sec (180% peak)
  • Starting torque: 150%
  • DC injection braking: ramp or coast to stop, adjustable, current limited
  • Electronic reversing
  • Adjustable accel/decel: 0.1 to 3600 sec (2 each)
  • Controlled speed range: 40:1
  • Critical frequency rejection: 2 selectable, adjustable bands
  • Drive efficiency: 96 to 98%
  • Energy $aving control: improves motor efficiency
  • Displacement power factor: 0.98
  • Output frequency: 0.1 to 400 Hz
  • Frequency resolution:
    0.01 Hz with digital reference, 
    0.06 Hz with analog reference
  • Frequency regulation: 
    0.01% digital (-10 ° to 40 °C),
    0.1% analog (15 ° to 35 °C)
  • Torque boost: full range, auto
  • Jog forward and reverse
  • Power loss ride-thru: 2 sec
  • Inertia ride-thru
  • Selectable auto restart after momentary power loss
  • Programmable auto restart (0 to 10 attempts) after resettable fault
  • Slip Compensation
Protective Features
  • Current limited stall prevention
  • Synchronized start into rotating motor via speed search
  • DC bus CHARGE indicator
  • Optically-Isolated controls
  • Phase-to-phase / phase-to-neutral short circuit protection
  • Ground fault protection
  • Electronic motor overload
  • Current and torque limit
  • Fault circuit: overcurrent, overvoltage, and overtemperature
  • Over torque protection
  • Under torque protection
Design Features
  • 32-bit microprocessor logic
  • Surface mount devices
  • Carrier frequency: selectable to 15 kHz
  • Keypad operator controls
  • LCD display: English alpha/numeric sixteen character two lines
  • 24 VDC control logic
  • Programmable contacts, one form C and one NO
  • Timer function: contact-initiated
  • RS-232 communications port
  • Volts/hertz ratio: Programmable custom V/Hz patterns
  • Multi-speed settings: 6 available
  • Remote speed reference:
    0 to 10 VDC or 4 to 20 mA
  • Setpoint (PID) control with inverse input and Sleep function
  • Signal follower: bias and gain
  • Analog monitor output: 0 to 10 VDC
  • NEMA 1 enclosed or protected chassis
  • UL, cUL and ce listed; IEC 146
  • MTBF: exceeds 28 years
Service Conditions
  • Ambient service temperature:
    -10°C to 40°C (104°F) NEMA 1, to 45°C (113°F) protected chassis
  • Humidity: non-condensing to 95%
  • Altitude: to 3300 ft; higher by derating
  • Input voltage: +10%/-15%, 500 to 600 VAC
  • Input frequency: 50/60 Hz ± 5%
  • 3-phase, 3-wire, phase sequence insensitive

Models & Ratings for P5 Drive 600 Volt


P5 600V Standard Drives - 2-200HP, 600V, NEMA 1 or protected chassis enclosure
Rated Input
Voltage
Drive Model Number
CIMR-P5
Rated Output Current (Amps)
Nominal HP
Standard Enclosure
600V
CIMR-P5M51P51
3.9
2 & 3
NEMA 1
CIMR-P5M53P71
7
5
CIMR-P5M55P51
11
7.5 & 10
600V
CIMR-P5M50111
19
15
NEMA 1
CIMR-P5M50151
25
20
CIMR-P5M50181
30
25
600V
CIMR-P5M50221
36
30
NEMA 1
CIMR-P5M50301
46
40
CIMR-P5M50371
58
50
600V
CIMR-P5M50451
69
60
NEMA 1
CIMR-P5M50551
86
75
CIMR-P5M50751
111
100
600V
CIMR-P5M50900
145
125 & 150
Protected Chassis