 ½ - 50 Horsepower HVAC-Specific AC Drive with 2-Contactor Bypass
The E7N Narrow Bypass package is a 2-contactor style bypass with HOA touchpad control, allowing motor operation from either the drive or across the line. This allows continued operation even if the E7 drive is disabled by fault or intention. Drive maintenance must be delayed until line power can be removed.
The E7N is a versatile narrow enclosure that meets the space requirements of end users and OEMs, yet has the flexibility to meet the varying requirements of specifying engineers and HVAC designers.
Yaskawa received a Building Operating Management Top Products Award which recognizes product releases that appeared on FacilitiesNet and generated the highest level of click-through interest from building and facility executives.
|
Specifications and Features for E7N Narrow Bypass Package
|
The E7N Bypass package is a 2-contactor style bypass with HOA touchpad control, allowing motor operation from either the drive or across the line. This allows continued operation even if the E7 drive is disabled, by fault or intention. Drive maintenance must be delayed until line power can be removed. The E7 and E7N Bypass have been designed for flexibility in providing the features and options commonly specified by facility designers.
The E7 Drive is a variable torque AC drive, designed specifically for HVAC applications in building automation. A new benchmark for size, cost, performance, benefits, and quality, the E7 includes numerous built-in features such as Network Communications, PI control and energy savings functions.
The E7 has embedded communications for the popular building automation protocols, Johnson Controls Metasys N2 and Siemens APOGEE, as well as Modbus. An optional LonWorks or BACnet interface card is available.
Performance Features
- VT Ratings: 1/2-25 HP, 208 VAC
1/2-50 HP, 480 VAC
- Overload capacity: 110% for 60 sec(150% peak)
- Starting torque: 100% at 3 Hz
- DC injection braking: at start or stop, adjustable, current limited (anti-windmill-ing)
- Motor preheat function
- Adjustable accel/decel: 0.1 to 6000 sec.
- Controlled speed range: 40:1
- Critical frequency rejection: 3 selectable,adjustable bands
- Current limiting: 30-180%
- Energy $aving control
- Torque boost: full range, automatic
- Power loss ride-thru: 2 seconds
- Inertia ride-thru
- Auto restart after power loss or resettable fault, selectable, programmable
- Feedback signal loss detection•Serial communication loss detection
- "Up/Down" floating point control capability
- Stationary motor auto-tuning
- Customizable monitor display
- Sleep function
- Run permissive input
- Ramp-to-stop or coast-to-stop selection
- Runtime changes in control and display
- Project-specific parameter reinitialization
- Copy keypad
Protective Features
- Current limited stall prevention
- Heat sink over-temperature, speed fold-back
- Cooling fan operating hours recorded
- Bi-directional start into rotating motor at synchronized speed
- DC bus charge indicator
- Current limiting DC bus fuse
- Optically-Isolated controls
- Short circuit protection: Phase-phase and phase-neutral
- Ground fault protection
- Electronic motor overload: UL
- Current and torque limit
- Fault display: last 10 faults
- Fault trace capabilities
- Over torque and under torque protection
- Program security code
- "Hunting" prevention logic
- Input source protection (MOVs)
- Input/output phase loss protection
E7N Available Options
- Circuit breaker (MCP) disconnect
- Main disconnect
- Semi-conductor fast acting fuses
- Drive input fused disconnect
- RFI cap network
- 3% or 5% line impedance
- LCD "Alpha" drive keypad
- Pneumatic pressure transducer : 3-15 psi
- BACnet and LonWorks communication
- Engraved nameplate
- 3-Contactor Bypass
|
Design Features
- 32-bit microprocessor logic
- Flash upgradeable firmware
- Non-volatile memory, program retention
- Surface-mount devices
- Displacement power factor: 0.98
- Output frequency: 0.1 to 120 Hz
- Frequency resolution: 0.06 Hz
- Frequency regulation: 0.1%
- Carrier frequency: selectable to 15 kHz
- 3% DC bus reactor: 40-60 HP, 480 VAC (optional on lower ratings)
- LED display
- 24 VDC control logic
- Transmitter/Option power supply
- Input/output terminal status
- Timer function: Elapsed time, Delay on start, Delay on stop
- Embedded Metasys N2, APOGEE FLN, and Modbus
- Volts/hertz ratio: Preset and programma-ble V/Hz patterns
- Remote speed command: 0-10 VDC or 4-20 mA, direct or reverse-acting
- Setpoint (PI) control with inverse or square root input, differential control via two feedback capability
- Feedback signal: low pass filter
- Speed command: bias and gain
- Meter Functions: Volt, amp, kilowatt, elapsed run time, speed command
- Output Current Transformers: qty 3
- UL, cUL listed and CE marked; IEC 146;
- MTBF: exceeds 28 years
Service Conditions
- Ambient Temperature: -10°C to 40°C (14° F to 104° F)
- Humidity: 95% RH, non-condensing
- Altitude: 3300 ft; higher by derate
- Input voltage: +10%/-15%
- Input frequency: 50/60 Hz ± 5%
- 3-phase, 3-wire, phase sequence insensitive
Bypass Features
- Bypass and Drive are factory assembled with Electronic Control System
- NEMA 1 metal enclosure standard
- Input disconnect switch with a lockable, through-the-door operating mechanism
- Sealed Bypass Control Keypad mounted on front door
- Integrated Drive touchpad control
- Drive Output and Bypass contactors
- Bi-metallic thermal overload relay, pro-vides motor protection in both the "drive" and "bypass" modes
- 120 VAC control power transformer
- Control and safety circuit terminal strip (Selectable for 120 VAC or 24 VDC input)
- Indicator LED’s for Control Power, Drive Ready, Drive Run, Drive Selected, Drive Fault, Drive Test, Bypass Selected, Bypass Run, Motor OL, Safety Open, Damper/BAS, Auto Run, Auto/Rem Transfer, Smoke Purge, Hand Mode, Off Mode, and Auto Mode
- 3 programmable Form C contacts (250 VAC, 1 Amp) for: Motor Run, Damper/BAS, Drive Run, Hand Mode, Auto Mode, Bypass Run, Fault or 1 select-able from the drive menu
- Remote Run/Stop via contact closure or serial communication
- Input speed command via 0-10 VDC, 4-20 mA or serial communication
- 2 Programmable analog outputs (0-10 VDC or 4-20 mA )
- Damper control circuit
- Programmable auto transfer to bypass on drive fault
- Remote transfer to bypass via contact closure
- Smoke purge function via contact closure
- Safety (freezestat, firestat, duct pressure, etc.) interlock
- Building Automation System (BAS) interlock
|
|
Models & Ratings for E7N Narrow Bypass Package
|
E7N Narrow Bypass - 1/2-50HP, 208 and 480V, 3-phase input, NEMA 1 enclosure, with factory installed and wired options
208V | 480V
|
Rated InputVoltage
|
Bypass Model Number
|
Rated Output Current (Amps)
|
Nominal HP1
|
|
208V
|
E7NVD002
|
2.4
|
1/2
|
|
E7NVD003
|
3.5
|
3/4
|
|
E7NVD004
|
4.6
|
1
|
|
208V
|
E7NVD007
|
7.5
|
2
|
|
E7NVD010
|
10.6
|
3
|
|
E7NVD016
|
16.7
|
5
|
|
208V
|
E7NVD024
|
24.2
|
7.5
|
|
E7NVD030
|
30.8
|
10
|
|
E7NVD046
|
46.2
|
15
|
|
208V
|
E7NVD059
|
59.4
|
20
|
|
E7NVD074
|
74.8
|
25
|
|
Rated InputVoltage
|
Bypass Model Number
|
Rated Output Current (Amps)
|
Nominal HP1
|
|
480V
|
E7NVB001
|
1.6
|
1/2
|
|
3/4
|
|
E7NVB002
|
2.1
|
1
|
|
480V
|
E7NVB003
|
3.4
|
2
|
|
E7NVB004
|
4.8
|
3
|
|
E7NVB007
|
7.6
|
5
|
|
480V
|
E7NVB011
|
11
|
7.5
|
|
E7NVB014
|
14
|
10
|
|
480V
|
E7NVB021
|
21
|
15
|
|
E7NVB027
|
27
|
20
|
|
E7NVB034
|
34
|
25
|
|
480V
|
E7NVB040
|
40
|
30
|
|
E7NVB052
|
52
|
40
|
|
E7NVB065
|
65
|
50
|
- Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors
|
|