Features :
|
Designed and Tested to meet Requirements of IEC 688 and IS 12784
|
|
Reliable SMD Technology
|
|
High Insulation Level
|
|
Higher load Capacity
|
|
Easy onsite conversion between DIN rail or Panel Mounting
|
|
Polycarbonate body, conforming to UL 94-VO
|
|
Measuring Quantity
|
AC Voltage
|
|
Nominal Input
|
0- 100V to 0 - 500V
|
|
Output Quantity
|
Independent DC Current or DC Voltage
|
|
Output Range
|
0-1 mA to 0-20mA/ 0-lVto0-10V Option : Dual Output
|
|
Ripple
|
<5% P-P
|
|
Output Burden
|
Current Output : Rext = 15V / I (full Scale) [750Ω @ 20mA or 1500Ω @ 10mA] ext = Output Voltage/ 20mA,
|
|
Auxiliary supply
|
AC 24V/ 110V/230V/400V AC/DC 24V...60V AC/DC 85V...230V
|
|
Power Consumption
|
< 4VA
|
|
Response Time
|
< 300ms (< 50ms optional)
|
|
High Insulation Level
|
3.7 kV
|
|
Impulse withstand Voltage
|
5kV, 1.2/50 µsec, 0.5 Ws.
|
|
Accuracy as per IEC 688
|
Class 0.5
|
|
Operating Temperature
|
-25 to 55°C
|
|